Product Description
- High Yield
- Multi MPPT with three level topology so peak efficiency of 98.9 %, Maximum in Inverter Industry.
- 10% Extra power on AC Side up to 45 degree.
- Up to 40 % Loading on DC Side for increasing generation.
- Integrated DC combiner box and DC/AC overvoltage protection so need to put additional String combiner Box.
- Anti-PID Recovery concept for protecting from module degradation.
- Forced Air cooling technology for fast cooling and longer life of product.
- Easy O &M
- Compact design and light weight for easy installation
- Latest Bluetooth technology-for fast and quick on-site monitoring.
- Plug-in design of IP68 fan and SPD, convenient for on-site maintenance
- Integrated string current monitoring function for fast trouble shooting
- Angular/Horizontal Installation as per site dimensions
- Remote firmware updating for parameter setting and firmware
- Grid Support
- Active & reactive power control and power ramp rate control
- Night SVG for reactive power supply.
- Compatible with all market available third party dataloggers/RTUs.
Input (DC)
Model | SG5KTL-MT |
Max. PV input voltage | 1100 V |
Min. PV input voltage / Startup input voltage | 200 V / 250 V |
Nominal input voltage | 600 V |
MPP voltage range | 200 – 1000 V |
MPP voltage range for nominal power | 240 – 850 V |
No. of independent MPP inputs | 2 |
Max. number of PV strings per MPPT | 1 |
Max. PV input current | 22A (11A / 11A) |
Max. current for input connector | 15 A |
Max. PV short-circuit current | 30 A (15A / 15A ) |
Output (AC)
AC output power | 5500 W @ 35 ℃ / 5000 W @ 45 ℃ |
Max. AC output current | 8.5 A |
Nominal AC voltage | 3 / N / PE, 230 / 400 V |
AC voltage range | 270 - 480 V |
Nominal grid frequency | 50 Hz / 45 |
Total Harmonic Distortion (THD) | < 3 % (at nominal power) |
DC current injection | < 0.5 % In |
Power factor | > 0.99 / 0.8 leading – 0.8 lagging |
Feed-in phases / Connection phases | 3 / 3 |
Efficiency
Max. efficiency | 98.4% |
Euro. efficiency | 97.6% |
Protection
PV reverse connection protection | Yes |
AC short-circuit protection | Yes |
Leakage current protection | Yes |
Grid monitoring | Yes |
PV string current monitoring | Yes |
DC switch | Yes** |
Overvoltage protection | DC Type II |
General Data
Dimensions (W x H x D) | 370*485*160 mm |
Weight | 20 kg |
Isolation method | Transformerless |
Degree of protection | IP65 |
Power loss in night mode | < 1 W |
Operating ambient temperature range | -25 to 60 ℃ (> 45℃ derating) |
Allowable relative humidity range (non-condensing) | 0 – 100% |
Cooling method | Natural cooling |
Max. operating altitude | 4000 m (> 2000 m derating) |
Display / Communication | LCD / Wi-Fi (optional) |
PV connection type | MC4 (Max. 6 mm² ) |
AC connection type | Plug and play connector (Max. 6 mm² ) |
Grid support | Active & reactive power control, power ramp rate control |