EAPRO 2000VA/24V SUNverter

Type

Select Quantity

Manufacturer
Eapro

Eapro Global Ltd

Founded

2012

Headquarter

India

Product Description
  • True hybrid solar PCU with 50amp. in built PWM solar charge controller.
  • Excellent Charging at low Mains voltage.
  • New Generation MOSFET based PWM technology with greater efficiency at lower cost Dynamic Stability.
  • User friendly graphic led panel Display defining working parameter of Power source for load.
  • Smart battery selection option with indicator.
  • Selector switch of ups/inv.& high/ low charging on the front bezel for ease of operation.
  • Enhanced Temperature Protection.
  • Complete protection of short circuit, phase reversal & overload.
  • Supports fully deep discharge batteries.
  • Internally selects solar distribution as per the load hence saves power & money by use SCA (Sun Clock Approximation).
  • Nominal Battery Voltage: 24VDC
  • Input Voltage Range (Normal Mode): 100 to 290 VAC+_ 10 VAC
  • Input Voltage Range (UPS Mode): 180 to 265 VAC+_ 10 VAC
  • Battery Selection Tubular, Flat, SMF/Loc.
  • Protections : Over Load, Short Circuit, PV Reverse Polarity Protection.
  • Solar Charge Controller Logic based on SUN Clock Approximation
BATTERY MODE 2000VA/24V
No Load Current @ Switch OFF ≤50mA
No Load Current @ Switch ON ≤1.8Amp
Output Voltage @ No LOAD 230V Nominal
Full LOAD Output Voltage @ 24VDC 210 ± 5 Volt.
Battery Current @ Full LOAD 62 ± 1 Amp.
Thermal Management Temperature Control by Fan

UPS MODE

Low Cut With Phase Match 180 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis from > Low Cut Voltage
High Cut With Phase Match 265 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis from < High Cut Voltage
Change Over Time From Mains To UPS ≤ 10msec
Change Over Time From UPS To Mains ≤ 10msec

NORMAL MODE

Low Cut With Phase Match 100 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis > Low Cut Voltage
High Cut With Phase Match 290 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis < High Cut Voltage
Change Over Time From Mains To UPS ≤ 40msec
Change Over Time From UPS To Mains ≤ 10msec

CHARGING MODE

Low Charging Current @ 220V AC (NC) 12.0 ± 1.0 Amp.
High Charging Current @ 220V AC (HC) 16.0 ± 1.0 Amp.
Battery Boost Voltage as per Table 'A'
Float Voltage 27.2 ± 0.4 Volt.

 